News

EMF Shielding in dB: Decibels and Percentages Explained

EMF Block

Translucent layers of navy and neutral fabric

What does 20 dB mean on a shielding report? Decibels describe a ratio, which makes them useful for comparing large changes in signal strength. Once you know what is being measured, the numbers become easier to read.

Here we explain 10, 20 and 30 dB using simple examples, then show you what else to look for in an EMF fabric report. These are mathematical examples, not ratings for our products.

Hypothetical power ratios: 10 dB leaves one tenth, 20 dB one hundredth, and 30 dB one thousandth of reference power; not product test results.
Illustrative dB-to-power conversions, not product test results.

Start with the two measurements

Shielding effectiveness compares a reference measurement with one taken using the shielding material or arrangement. To read a result such as 30 dB, you also need the frequency, sample and test setup.

The Rohde & Schwarz shielding-measurement application note shows how reference calibration, frequency and measurement position are used in a controlled equipment test. The same need for clearly defined conditions helps explain how to read a fabric report.

What dB means in a power comparison

The NIST guide to logarithmic quantities distinguishes power ratios from field-amplitude ratios. For a power-based attenuation calculation, shielding effectiveness in dB is 10 times the base-10 logarithm of reference power divided by transmitted power.

You do not need to use logarithms while shopping. In that defined power comparison, each additional 10 dB means one tenth as much transmitted power relative to the reference:

  • 10 dB: one tenth remains, equivalent to 90% less transmitted power.
  • 20 dB: one hundredth remains, equivalent to 99% less transmitted power.
  • 30 dB: one thousandth remains, equivalent to 99.9% less transmitted power.

These conversions apply to the defined power comparison. They do not describe total exposure around a person.

Why “99%” needs a quantity attached

Power and electric-field amplitude are not the same quantity. Field-amplitude ratios use a factor of 20 in the logarithmic expression, whereas power ratios use 10. Under the conditions connecting power to the square of field amplitude, a 20 dB reduction corresponds to one tenth of the field amplitude, but one hundredth of the power. That is 90% less amplitude and 99% less power.

The same attenuation can therefore have different percentages depending on the quantity. When reading a percentage, check whether it describes power or field amplitude. The report should identify which was measured.

Compare the remaining signal

Imagine two hypothetical measurements, made under otherwise identical conditions, giving 20 dB and 30 dB. The remaining power fractions are 0.01 and 0.001 of the reference. The second is ten times smaller, although the reduction percentages differ by only 0.9 percentage points.

Small differences in percentage can represent much larger differences in the remaining signal. Compare the dB values alongside the frequency and sample details to see whether two results are comparable.

If you are comparing reports, note the measured dB value and its frequency. Put any percentage you calculate beside it and label that figure as a conversion.

Read the result across the frequency range

Many reports show a graph or a table because performance changes with frequency. Read the values at the frequencies relevant to your question rather than relying only on the highest number.

The published scope of ASTM D4935, for example, concerns planar materials and defined far-field conditions. Its method description identifies a 30 MHz to 1.5 GHz range. Read the procedure and any stated modifications alongside the results to understand the range actually measured.

Check whether a value was measured at that frequency or estimated from other measurements. If the report is unclear, ask before using the figure to compare fabrics.

How fabric tests differ from worn clothing

A fabric sample sits in a defined test arrangement. A worn garment has seams, openings and edges, and it moves with you. That is why a fabric result is not a rating for a complete outfit.

Two clothing layers also need their own assessment. You cannot add their individual fabric ratings to calculate the shielding of a layered outfit.

Fabric performance, finished-garment performance and health outcomes are separate questions. A textile measurement answers only the first.

Use the report alongside garment details

Our women’s sleeveless top, model AJ511, is a sleeveless option to explore by neckline, body length and fit. For any dB figure, check that the report identifies the same fabric.

Need help with a number? Contact us with the product name and the report or figure you are reading.

Material names can also help you identify what was tested. Our conductive-fabric label guide explains the composition terms you may see alongside shielding measurements.

Compare like-for-like results when they are available. Otherwise, choose by the garment’s stated composition, construction and fit without assigning it a guessed rating.

Women’s sleeveless top, model AJ511
Women’s sleeveless top, model AJ511. Product illustration.

Your shielding-report checklist

  1. Identify the exact product or fabric version tested.
  2. Check whether the percentage describes power or field amplitude.
  3. Locate the measured frequency range and the corresponding values.
  4. Read the reference setup, specimen arrangement and condition.
  5. Keep your calculated conversion labelled separately from the reported measurement.
  6. Check whether the result covers a fabric sample or the complete garment; neither alone demonstrates a health benefit.

What a shielding number cannot tell you about health

ARPANSA states that there is no substantiated evidence of adverse health effects from low-level RF exposure below its limits. A fabric's attenuation result, even when valid, does not demonstrate prevention or treatment of a health condition.

The most useful dB comparison identifies what was measured, at which frequency and under which conditions. Keep those details with the number, and contact us if you need help understanding a term.